Development of a water stoppage technique using the photo-curable resin for decommissioning

島田 梢; 大岡 誠; 前川 康成*; 富塚 千昭; 片桐 源一*; 青柳 克弘*; 柴田 卓弥; 小山 真一

no journal, , 

Several water leakage cases at Fukushima-Daiichi Nuclear Power Station (1F) have been reported. Therefore, water leakage stoppage techniques of the remote operation are required under high level radioactivity. In this study, we investigated basic properties of the photo-curable resin (PCR) in water, and applicability of the PCR to the water leakage stoppage. As the result, a water dispersion type of PCR was cured by the ultraviolet (UV) irradiation. This report suggests the PCR as one of the technique to stop the water leakage for the 1F decommissioning.

口頭

Evaluation of concrete properties by laser induced ultrasonic waves for reactor decommissioning

山田 知典; 羽成 敏秀; 柴田 卓弥; 西村 昭彦; 小山 真一; 大道 博行; 島田 義則*; Kotyaev, O.*; 倉橋 慎理*

no journal, , 

福島第一原子力発電所の廃止措置において、放射性物質によって汚染された大量の廃棄物等を処理することが喫緊の課題である。放射性廃棄物の処理を効率的に進めるためには、放射性廃棄物の性状を分析し把握する必要がある。しかしながら、高放射線量下での作業となるため、直接作業が行えない。そこで、遠隔分析が可能なレーザー技術を駆使した熱劣化コンクリートの物理的・機械的特性等の遠隔診断評価を行った。本研究では、レーザードップラー振動計を用いて、コンクリート中を通過する超音波の伝播時間の非接触測定を行った。その結果、熱処理によって劣化したコンクリートは超音波の伝搬時間が長くなることが分かった。この超音波の伝播時間の差は、熱処理に起因するコンクリートの物理的および機械的特性の変化に依存すると考えられる。以上のことから、レーザードップラー振動計は対象物中を伝播する超音波を計測することでコンクリートの熱劣化を評価できる有望なツールであると期待できる。